Getting Ready for Energy-Efficient Networking                R. C. Sofia
Internet-Draft                                                    D. Ali
Intended status: Informational                              fortiss GmbH
Expires: 7 January 2026                                      6 July 2025


              Energy-aware Differentiated Services (EA-DS)
               draft-sofia-green-energy-aware-diffserv-00

Abstract

   This document proposes to extend the Differentiated Services
   (DiffServ) Quality of Service (QoS) model to support energy-efficient
   networking.  As a first draft, it discusses how such extensions could
   be done, bringing first examples of energy-efficiency metrics that
   could be applied to mark traffic, and providing routing applicability
   examples by interpreting existing or experimental DSCP codepoints to
   represent not only traditional QoS parameters (e.g., latency,
   jitter), but also application-level energy sensitivity.  By
   incorporating energy metrics into traffic classification, network
   devices and orchestrators can make routing and resource allocation
   decisions that optimize both service performance and energy
   consumption.

Status of This Memo

   This Internet-Draft is submitted in full conformance with the
   provisions of BCP 78 and BCP 79.

   Internet-Drafts are working documents of the Internet Engineering
   Task Force (IETF).  Note that other groups may also distribute
   working documents as Internet-Drafts.  The list of current Internet-
   Drafts is at https://datatracker.ietf.org/drafts/current/.

   Internet-Drafts are draft documents valid for a maximum of six months
   and may be updated, replaced, or obsoleted by other documents at any
   time.  It is inappropriate to use Internet-Drafts as reference
   material or to cite them other than as "work in progress."

   This Internet-Draft will expire on 7 January 2026.

Copyright Notice

   Copyright (c) 2025 IETF Trust and the persons identified as the
   document authors.  All rights reserved.






C. Sofia & Ali           Expires 7 January 2026                 [Page 1]

Internet-Draft            Energy-aware DiffServ                July 2025


   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents (https://trustee.ietf.org/
   license-info) in effect on the date of publication of this document.
   Please review these documents carefully, as they describe your rights
   and restrictions with respect to this document.  Code Components
   extracted from this document must include Revised BSD License text as
   described in Section 4.e of the Trust Legal Provisions and are
   provided without warranty as described in the Revised BSD License.

Table of Contents

   1.  Introduction  . . . . . . . . . . . . . . . . . . . . . . . .   3
     1.1.  Requirements Language . . . . . . . . . . . . . . . . . .   3
     1.2.  Problem Statement . . . . . . . . . . . . . . . . . . . .   4
     1.3.  Scope and Applicability . . . . . . . . . . . . . . . . .   4
     1.4.  Definitions . . . . . . . . . . . . . . . . . . . . . . .   5
   2.  Energy-awareness and Node, Link, Path Telemetry
           Considerations  . . . . . . . . . . . . . . . . . . . . .   6
   3.  Energy-aware DSCP Mapping . . . . . . . . . . . . . . . . . .   7
   4.  Routing Behaviour . . . . . . . . . . . . . . . . . . . . . .   9
     4.1.  Example: Minimize Link Energy . . . . . . . . . . . . . .  10
     4.2.  Example: Lowest Total Energy (Links and Nodes)  . . . . .  11
     4.3.  Example: Lowest Energy-Load Preference  . . . . . . . . .  11
     4.4.  Example: No energy-awareness Preference . . . . . . . . .  12
   5.  Telemetry and Probing for Energy-aware Routing
           Considerations  . . . . . . . . . . . . . . . . . . . . .  12
     5.1.  Passive Probing . . . . . . . . . . . . . . . . . . . . .  12
     5.2.  Active Probing  . . . . . . . . . . . . . . . . . . . . .  12
     5.3.  Hybrid Approaches . . . . . . . . . . . . . . . . . . . .  13
   6.  IANA Considerations . . . . . . . . . . . . . . . . . . . . .  14
   7.  Security Considerations . . . . . . . . . . . . . . . . . . .  14
     7.1.  DSCP Misuse and Traffic Reclassification  . . . . . . . .  14
     7.2.  Control Plane Manipulation  . . . . . . . . . . . . . . .  14
     7.3.  Privacy Preservation  . . . . . . . . . . . . . . . . . .  15
     7.4.  Energy Specific Threats . . . . . . . . . . . . . . . . .  15
     7.5.  Inter-domain Trust and Policy Consistency . . . . . . . .  15
   8.  References  . . . . . . . . . . . . . . . . . . . . . . . . .  16
     8.1.  Normative References  . . . . . . . . . . . . . . . . . .  16
     8.2.  Informative References  . . . . . . . . . . . . . . . . .  16
   Acknowledgements  . . . . . . . . . . . . . . . . . . . . . . . .  17
   Authors' Addresses  . . . . . . . . . . . . . . . . . . . . . . .  17










C. Sofia & Ali           Expires 7 January 2026                 [Page 2]

Internet-Draft            Energy-aware DiffServ                July 2025


1.  Introduction

   Energy efficiency and sustainability are becoming design priorities
   in data communications, driven by the increasing complexity of ultra-
   dense, heterogeneous mobile network environments and the
   proliferation of mobile, decentralized applications.  These
   applications often demand not only high processing power and
   bandwidth, but also bounded latency guarantees.  At the same time,
   several international efforts are aligning with global net-zero
   objectives, investing in energy-optimized infrastructures, relying on
   Artificial Intelligence (AI)-based power management, renewable energy
   integration, and intelligent resource allocation strategies spanning
   both hardware and software development.  As discussed in initiatives
   such as GREEN and the IRTF SUSTAIN research group, there is a growing
   need to integrate energy awareness into the broader operation of
   communication networks.  This includes embedding energy
   considerations into the routing and forwarding processes, which are
   traditionally optimized solely for performance metrics.  In this
   context, the present work proposes extending Quality of Service (QoS)
   models by incorporating energy-specific metrics as first-class
   parameters.  Integrating energy sensitivity into QoS models offers
   tangible benefits across network management and operations.  However,
   it also introduces new challenges: how to effectively express and
   signal energy metrics, how to gather and interpret the required
   telemetry, and how to manage the trade-offs between energy savings,
   system complexity, and performance.  To address this, this draft
   specifically focuses on how such integration would fit the
   Differentiated Services (DiffServ) model as defined in [RFC2474] and
   [RFC2475].  The approach is to interpret existing and experimental
   DiffServ Code Points (DSCP) to encode both application-level QoS
   requirements and energy-related constraints.  By doing so, network
   elements such as routers, switches, and orchestrators can make
   resource allocation and forwarding decisions that take into account
   energy-sensitivity parameters, such as power consumption or CO2
   footprinting.  This enables a more energy-efficient network behavior
   without compromising service-level expectations.

1.1.  Requirements Language

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
   "OPTIONAL" in this document are to be interpreted as described in BCP
   14 [RFC2119] [RFC8174] when, and only when, they appear in all
   capitals, as shown here.







C. Sofia & Ali           Expires 7 January 2026                 [Page 3]

Internet-Draft            Energy-aware DiffServ                July 2025


1.2.  Problem Statement

   As networks and internet applications evolve from real-time control
   systems to data-intensive analytics heavily involving AI workloads,
   the need to manage both performance and energy efficiency during
   networking operations, such as routing, is becoming increasingly
   critical.  Quality of Service (QoS) models such as the Differentiated
   Services (DiffServ) [RFC2474][RFC2475] offer well-established
   frameworks for expressing and enforcing QoS application requirements
   in the form of latency, jitter, packet loss, among others.  However,
   the modern shift toward decentralized architectures, such as multi-
   tenant, heterogeneous, and dynamic edge-cloud environments, demands a
   dual operational objective: maintaining service quality while
   minimizing energy consumption.  Applications now vary not only in
   their strict traditional QoS constraints, but also in their energy
   sensitivity and adaptability.  For instance, an Internet of Things
   (IoT) telemetry flow may tolerate delayed or batched delivery to
   reduce energy use, while a control loop for an industrial system may
   demand immediate and high-energy processing regardless of cost.  In
   the absence of mechanisms to signal such energy-related requirements
   within a QoS model like DiffServ, network elements and orchestration
   systems lack the information needed to make coordinated decisions
   that optimize for both energy and performance, while meeting
   application-level requirements.  Enabling such integration would
   support dynamic, intelligent traffic handling, including energy-aware
   routing ("green" routing), scaling of compute resources based on
   traffic class, or even energy-based preemption, while still
   respecting application-level QoS expectations.  DiffServ provides a
   scalable approach to classifying and prioritizing traffic using
   Differentiated Services Code Points (DSCP).  It effectively addresses
   performance-related service differentiation, but, similarly to other
   QoS models, it is agnostic to the energy consumption of the
   underlying infrastructure, whether in the forwarding paths or in the
   compute nodes executing workloads.  As such, extending DiffServ to
   incorporate energy-awareness is a timely and necessary evolution to
   support sustainable, energy-efficient, and policy-aligned networking
   in increasingly complex and environmentally conscious operational
   environments.

1.3.  Scope and Applicability

   The energy-aware discussion on extensions to DiffServ proposed in
   this document is applicable in environments where fine-grained policy
   enforcement, traffic classification, and telemetry-driven routing or
   scheduling are operationally feasible.  The work is primarily
   applicable to multi-tenant federated edge-cloud environments where
   energy-sensitive networking policies are relevant.  These include:




C. Sofia & Ali           Expires 7 January 2026                 [Page 4]

Internet-Draft            Energy-aware DiffServ                July 2025


   *  Cloud-edge computing infrastructures, especially those integrating
      AI workloads or energy-constrained nodes.

   *  Industrial IoT environments, where specific classes of traffic
      (e.g., control loops vs. telemetry) exhibit distinct energy and
      latency requirements.

   *  Software-defined WANs (SD-WANs) deployments, where centralized
      controllers manage QoS and routing policies.

   *  Federated edge-cloud platforms, such as those based on CODECO,
      where energy efficiency is a key orchestration objective.

   These scenarios typically involve DSCP marking and enforcement at
   ingress points, real-time or periodic energy/load telemetry
   collection, and centralized or distributed routing logic.  The
   proposed approach assumes that DSCP markings are respected across the
   path and that telemetry is exposed with sufficient granularity, with
   attention to privacy

1.4.  Definitions

   Latency:
      (also known as bounded latency) refers to the end-to-end
      transmission delay between a sender and a receiver when a traffic
      flow is initiated by an application.  By definition, latency
      corresponds to the time interval between the sending of the first
      packet of a flow from a source to a destination and the time at
      which the last packet of that flow is received

   Node energy, n_e(i)
      is the amount of energy (typically measured in Joules or Watts
      over time) consumed by a node to host, process, and serve
      workloads, including compute, memory, storage, and network
      interface activity.

   Node load
      CPU, memory, or I/O resource usage that may affect dynamic energy
      consumption and thermal management.

   Link energy, l_e(i,j)
      The amount of energy (typically measured in milliJoules per bit
      (mJ/bit) or Watts) consumed by the transmission of data across a
      network connection between two nodes, including switches, routers,
      and network interface cards (NICs) involved in the path.






C. Sofia & Ali           Expires 7 January 2026                 [Page 5]

Internet-Draft            Energy-aware DiffServ                July 2025


   Link load, l(i,j)
      The current traffic load (e.g., as a percentage of link capacity),
      which can affect both latency and energy cost.

   Energy sensitivity
      A qualitative or quantitative indication of how tolerant a given
      application or flow is to variations in energy consumption (e.g.,
      delay to save power, or no tolerance at all).

2.  Energy-awareness and Node, Link, Path Telemetry Considerations

   To enable energy-aware routing and resource management, network
   elements MUST have access to timely, accurate telemetry about the
   energy consumption and utilization characteristics of both nodes and
   links.  This information allows the control or data plane to make
   informed decisions about path selection and traffic treatment based
   not only on traditional QoS metrics (e.g., delay, jitter, loss), but
   also on energy-related factors.  To enforce energy-aware policies,
   networking nodes MUST expose telemetry on:

   *  Node energy.

   *  Node usage

   *  Link energy.

   *  Link usage

   Network nodes MAY also expose telemetry on other parameters such as:

   *  Node power state transition (e.g., idle, transmit, receive modes).

   *  Other energy related metrics, such as CO2 footprint.

   A combined path energy cost can be computed by aggregating both node
   and link energy metrics along a given forwarding path.  Formulations
   of some of these metrics can be found in related initiatives.  As a
   representative example, this work references node and link energy/
   load metrics used in the CODECO edge-cloud container orchestration
   framework [codeco].  While CODECO offers a practical implementation
   of energy metric collection and usage, the definitions and methods
   presented here are not exclusive to CODECO and can be generalized to
   other orchestration or telemetry frameworks.  Hence, the metrics
   defined in CODECO deliverable D10 [codeco_d10] offer a compute- and
   network-oriented view of energy metrics and can serve as a useful
   reference for exploring how similar principles might be applied to
   DiffServ-based QoS extensions.  These metrics are illustrative and
   not prescriptive, and alternative formulations or telemetry models



C. Sofia & Ali           Expires 7 January 2026                 [Page 6]

Internet-Draft            Energy-aware DiffServ                July 2025


   may be equally valid.  Such telemetry can serve as input for policy
   engines or SDN controllers in future DiffServ extensions.  In
   particular, the CODECO framework defines:

   *  Node energy as n_e(i): Per-node energy over time, aggregated from
      system sensors.

   *  Link energy, l_e(i,j): Dynamic energy cost for traffic across
      interface j of node i, derived from interface statistics and
      probing.

   *  Node usage: % of CPU available derived from interface statistics
      and probing.

   *  Link usage, l: traffic across interface j of node i, derived from
      interface statistics and probing.

3.  Energy-aware DSCP Mapping

   The DSCP field provides a 6-bit space in the IP header used to
   classify traffic into Per-Hop Behaviors (PHBs), as defined in
   [RFC2474] and further elaborated in [RFC4594].  This document
   proposes extending the semantics of selected DSCP values to encode
   energy sensitivity, in addition to traditional QoS dimensions such as
   latency, jitter, and packet loss.  Table 1 provides a representative
   mapping of DSCP values to energy-aware service classes.  Where
   possible, this mapping is aligned with the traffic classes and PHBs
   defined in RFC 4594, ensuring backward compatibility and operational
   consistency.  Additionally, a subset of experimental DSCP values
   (from the local/experimental range) is introduced to support emerging
   use cases in energy-aware networking environments.  Each DSCP class
   in the table is annotated with an intended energy sensitivity, an
   example use case, and a recommended policy behavior.  These
   annotations are illustrative and meant to guide implementations that
   wish to leverage DiffServ for integrated energy and performance-aware
   traffic treatment.  Experimental DSCP values (e.g., 0x2E, 0x1A, 0x0A)
   are intended for closed or federated environments where domain-wide
   agreement on codepoint interpretation is feasible.  These enable
   finer-grained control over routing or resource scheduling policies
   that optimize for energy efficiency alongside service quality.

   +=====+====+============+===========+============+==================+
   |DSCP |PHB |RFC 4594    |Energy     |Example     | Example          |
   |Value|Name|Traffic     |Sensitivity|Usage       | Recommended      |
   |     |    |Class       |           |            | Behaviour        |
   +=====+====+============+===========+============+==================+
   |46   |EF  |Real-Time   |Ignore     |VoIP,       | Route via path   |
   |     |    |Interactive |           |industrial  | with lowest      |



C. Sofia & Ali           Expires 7 January 2026                 [Page 7]

Internet-Draft            Energy-aware DiffServ                July 2025


   |     |    |            |           |control     | latency and      |
   |     |    |            |           |            | jitter; energy   |
   |     |    |            |           |            | cost not         |
   |     |    |            |           |            | considered       |
   +-----+----+------------+-----------+------------+------------------+
   |34   |AF41|Broadcast   |Moderate   |Real-time HD| Prefer low-      |
   |     |    |Video       |           |video       | latency and      |
   |     |    |            |           |            | low-loss paths   |
   |     |    |            |           |            | with moderate    |
   |     |    |            |           |            | energy           |
   |     |    |            |           |            | awareness        |
   +-----+----+------------+-----------+------------+------------------+
   |26   |AF31|Multimedia  |Moderate   |Interactive | Route via        |
   |     |    |Conferencing|           |conferencing| medium-energy,   |
   |     |    |            |           |            | lightly loaded   |
   |     |    |            |           |            | paths to         |
   |     |    |            |           |            | balance latency  |
   |     |    |            |           |            | and energy-      |
   |     |    |            |           |            | efficiency       |
   +-----+----+------------+-----------+------------+------------------+
   |18   |AF21|High        |High       |AI/ML batch | Prefer energy-   |
   |     |    |Throughput  |           |jobs, smart | efficient        |
   |     |    |Data        |           |uploads     | routes even if   |
   |     |    |            |           |            | slightly higher  |
   |     |    |            |           |            | delay; include   |
   |     |    |            |           |            | load balancing   |
   +-----+----+------------+-----------+------------+------------------+
   |10   |AF11|Low-Latency |High       |Firmware    | Select           |
   |     |    |Data        |           |updates,    | underutilized,   |
   |     |    |            |           |telemetry   | low-energy       |
   |     |    |            |           |sync        | paths, tolerate  |
   |     |    |            |           |            | variable         |
   |     |    |            |           |            | latency          |
   +-----+----+------------+-----------+------------+------------------+
   |8    |CS1 |Background  |Very High  |Backups,    | Route via        |
   |     |    |Data        |           |logs, cold  | lowest-energy,   |
   |     |    |            |           |storage     | longest-delay    |
   |     |    |            |           |            | paths;           |
   |     |    |            |           |            | preemptable      |
   |     |    |            |           |            | traffic          |
   +-----+----+------------+-----------+------------+------------------+
   |0    |BE  |Best Effort |Max energy |Non-critical| Allow            |
   |     |    |            |savings    |data        | opportunistic    |
   |     |    |            |           |transfer    | routing;         |
   |     |    |            |           |            | energy-          |
   |     |    |            |           |            | efficiency       |
   |     |    |            |           |            | maximized, no    |
   |     |    |            |           |            | performance      |



C. Sofia & Ali           Expires 7 January 2026                 [Page 8]

Internet-Draft            Energy-aware DiffServ                July 2025


   |     |    |            |           |            | guarantee        |
   +-----+----+------------+-----------+------------+------------------+
   |0x2E |EXP |Experimental|Low        |Secure,     | Route through    |
   |     |    |Use (High   |           |energy-     | secure but       |
   |     |    |Priority)   |           |sensitivity | energy-aware     |
   |     |    |            |           |critical    | paths;           |
   |     |    |            |           |flows       | monitored for    |
   |     |    |            |           |            | telemetry        |
   |     |    |            |           |            | feedback         |
   +-----+----+------------+-----------+------------+------------------+
   |0x1A |EXP |Experimental|Moderate   |Distributed | Trade-off        |
   |     |    |Balanced    |           |compute jobs| between energy   |
   |     |    |Load        |           |            | cost and         |
   |     |    |            |           |            | congestion       |
   |     |    |            |           |            | across nodes     |
   |     |    |            |           |            | and links        |
   +-----+----+------------+-----------+------------+------------------+
   |0x0A |EXP |Experimental|Very High  |Delay-      | Explicitly       |
   |     |    |Energy Saver|           |tolerant    | prefer energy-   |
   |     |    |            |           |batch       | minimizing       |
   |     |    |            |           |processing  | paths;           |
   |     |    |            |           |            | opportunistic    |
   |     |    |            |           |            | or deferred      |
   |     |    |            |           |            | routing          |
   +-----+----+------------+-----------+------------+------------------+

          Table 1: Energy-aware DSCP Mapping Aligned with RFC 4594

4.  Routing Behaviour

   Network elements and orchestrators MAY implement routing and
   scheduling decisions that consider both the DSCP value (as a proxy
   for energy sensitivity) and real-time energy metrics collected from
   network nodes and links.  A few examples based on the Figure 1
   topology:
















C. Sofia & Ali           Expires 7 January 2026                 [Page 9]

Internet-Draft            Energy-aware DiffServ                July 2025


                        R1
                     /     \
        l_e=1.2,l=60%     l_e=1.0,l=50%
                 /             \
               A                 B
                \               /
        l_e=0.8,l=40%     l_e=0.6,l=35%
                  \       /
                   R2----------\
                    |           \
        l_e=0.7,l=30%             \ l_e=0.6,l=25%
                    |             \
                    C--------------D
                  /                 \
        l_e=0.5,l=20%           l_e=0.4,l=15%
                /                   \
             (1)                   (2)  (Source and Destination)

     Figure 1: Example topology with link and node Energy/Load Metrics.

   Where:

   *  (1) Source node.

   *  (2) Destination node

   *  R1, R2 routers

   *  A, B, C, D: Intermediate access routers/edge nodes

   Between nodes, each link has the following costs:

   *  e = energy per bit (in mJ/bit).

   *  l = current load (in % usage)

4.1.  Example: Minimize Link Energy

   The aim is to define a policy that always selects links with lowest
   energy, independently of node energy or load.  Here, delay-tolerant
   or low-priority traffic WOULD be routed via links that overall
   provide the minimum cumulative energy cost, independently of the node
   location, number of hops, or total latency.

   *  Selected path: 1 -- C --D --2

   *  Link Costs:




C. Sofia & Ali           Expires 7 January 2026                [Page 10]

Internet-Draft            Energy-aware DiffServ                July 2025


   *  1--C: 0.5, C--D: 0.4, D--2: 0.4 = 1.3 mJ/bit total link energy

   *  Alternative Path (e.g., via R1): much higher link energy (1.2+1.0)

   *  DSCP: CS1 (8) or BE (0)

   *  Traffic example: Background data sync, logs

4.2.  Example: Lowest Total Energy (Links and Nodes)

   The aim is to define a policy that results in the selection of routes
   with both total lowest cumulative energy, and low utilization,
   considering both link and node load.

   *  Candidate Path: 1 --C --R2 --B --2

   *  Link energy: 0.5 + 0.7 + 0.6 + 0.6 = 2.4

   *  Node energy: C (0.6) + R2 (0.9) + B (1.0) = 2.5

   *  Total = 4.9 mJ/bit

   *  Alternative path via R1 has total energy = 6.0+ mJ/bit

   *  DSCP: AF31 (26) or AF21 (18)

   *  Traffic example: Analytics, smart batching apps

4.3.  Example: Lowest Energy-Load Preference

   The aim of this policy would be to consider a combination of energy
   and load, to ensure that traffic WOULD be routed over nodes that can
   offer the path with low energy and also low usage:

   *  Candidate Path: 1 --C --R2 --D --2

   *  Load: C -- 20%, R2 -- 30%, D -- 15%, links -- 25-30%

   *  Energy: C + R2 + D = 0.6 + 0.9 + 0.5 = 2.0 mJ (nodes)

   *  Links 2.0 mJ --Total 4.0 mJ

   *  DSCP: AF11 (10) or Experimental (0x30)

   *  Traffic Type: Opportunistic jobs like firmware updates or
      distributed computations where network and compute utilization
      should be minimized.




C. Sofia & Ali           Expires 7 January 2026                [Page 11]

Internet-Draft            Energy-aware DiffServ                July 2025


4.4.  Example: No energy-awareness Preference

   In this example, the DSCP marking would allow routers to ignore any
   energy preference, ensuring a traditional expedited treatment.

   *  Path Selected: 1 --C --R2 --A --R1 --B --2

   *  DSCP Mapping: EF (DSCP 46)

   *  Traffic Type: Real-time voice/video or control systems

5.  Telemetry and Probing for Energy-aware Routing Considerations

   Energy-aware service differentiation requires accurate, real-time
   insights into the state of the network, particularly with respect to
   energy consumption and resource load.  Such insights can be gathered
   through two primary telemetry mechanisms: passive or active (in-band)
   probing.

5.1.  Passive Probing

   Passive probing refers to the collection of performance and usage
   metrics by observing ongoing traffic without modifying it.  Common
   methods include flow monitoring (e.g., NetFlow, IPFIX), SNMP-based
   counters, interface statistics, and network tap-based analytics.
   Passive probing is advantageous due to its low intrusiveness, wide
   support in existing infrastructure, and suitability for long-term
   trend analysis.  However, it typically lacks real-time granularity,
   does not reflect per-packet variation, and often provides limited
   insight into specific in-network behavior such as queuing delay or
   microbursts.  Passive probing is beneficial to bring a fine-grained
   perspective on energy sensitivity based on:

   *  Interface energy counters (if supported by hardware)

   *  Node CPU/memory utilization

   *  Link usage

5.2.  Active Probing

   Active probing (or in-band telemetry) involves the use of explicit
   probes or modifications to data-plane packets to embed monitoring
   information.  This includes:

   *  In-situ Operations, Administration, and Maintenance (IOAM)
      [RFC9197]




C. Sofia & Ali           Expires 7 January 2026                [Page 12]

Internet-Draft            Energy-aware DiffServ                July 2025


   *  In-band Network Telemetry (INT) using programmable data planes
      (e.g., P4)

   *  Application-layer probes for measuring latency and loss

   *  Synthetic probing (e.g., ping, traceroute with extensions)

   Active probing allows for per-hop, per-packet collection of:

   *  Processing delay

   *  Queue depth

   *  Path-level latency and jitter

   *  Node and link identifiers

   *  (Optionally) energy cost annotations per segment

   This level of visibility is especially valuable for adaptive, energy-
   aware routing decisions.  For example, flows marked with energy-
   sensitive DSCP values may be routed dynamically based on the measured
   per-path energy profile, using IOAM metadata.  However, in the
   context of edge-cloud multi-tenant, federated environments, active
   probing may increase the overall operational inherent to deploying a
   monitoring architecture across mobile, heterogeneous large-scale
   edge-cloud environments.

5.3.  Hybrid Approaches

   In practice, energy-sensitive service differentiation may benefit
   from a combination of passive and active mechanisms.  Passive metrics
   can provide baseline load and energy cost estimates, while active
   probing offers precision feedback for high-priority or adaptive
   flows.  Control planes (e.g., SDN controllers or orchestrators) can
   use telemetry to:

   *  Select energy-efficient paths for DSCP classes that tolerate delay

   *  Adjust queue policies or scheduling weights in real-time

   *  Trigger re-marking or flow deferral when energy thresholds are
      reached

   Probing systems MUST ensure time-synchronization and data fidelity if
   they are used for per-hop energy optimization.  Energy-related
   telemetry formats and reporting intervals SHOULD be aligned with
   flow-level characteristics to avoid overreaction or instability.



C. Sofia & Ali           Expires 7 January 2026                [Page 13]

Internet-Draft            Energy-aware DiffServ                July 2025


6.  IANA Considerations

   This document does not request IANA action but suggests using DSCP
   values in the experimental or local-use ranges for energy-aware
   extensions.

7.  Security Considerations

   Energy-aware Differentiated Services introduce several new potential
   attack vectors and privacy implications beyond those already present
   in traditional DiffServ and QoS mechanisms.

7.1.  DSCP Misuse and Traffic Reclassification

   This work proposes to rely on experimental DSCP values to signal
   energy sensitivity and influence routing and scheduling decisions.
   Malicious or misconfigured endpoints could falsely mark traffic to
   gain preferential treatment, such as being routed through energy-
   saving paths or low-congestion nodes.  To mitigate this, networks
   SHOULD:

   *  Enforce DSCP re-marking at domain ingress (e.g., at provider or
      enterprise edges)

   *  Authenticate or validate traffic classification based on
      application profiles or identity

   *  Restrict high-sensitivity DSCP values (e.g., EF or experimental
      green classes) to trusted endpoints

7.2.  Control Plane Manipulation

   Energy-aware routing relies on telemetry and policy interpretation at
   centralized or distributed control planes.  Attackers who gain access
   to these systems could manipulate:

   *  Energy metrics to bias routing

   *  Load reports to induce congestion

   *  Path computation engines to direct traffic inefficiently or
      disrupt service

   Control planes MUST be protected using standard practices:

   *  Mutual authentication between controllers and forwarding devices

   *  Role-based access control (RBAC) for orchestration systems



C. Sofia & Ali           Expires 7 January 2026                [Page 14]

Internet-Draft            Energy-aware DiffServ                July 2025


   *  Secure telemetry channels (e.g., TLS, IPsec)

7.3.  Privacy Preservation

   Probing mechanisms, in particular active probing, may expose internal
   node performance, energy use, and utilization patterns.  This can
   leak information about the network's architecture, topology, or
   workload behaviour.  Networks SHOULD:

   *  Limit the telemetry scope (e.g., aggregate rather than per-packet
      reporting)

   *  Apply encryption or anonymization where telemetry crosses trust
      boundaries

   *  Use access controls for telemetry consumers and collectors

7.4.  Energy Specific Threats

   Manipulating energy-related behavior may not only degrade QoS but
   also undermine broader sustainability goals.  Attackers may attempt
   to:

   *  Overload energy-efficient paths to force fallback to high-
      consumption infrastructure

   *  Create asymmetric energy drain in multi-tenant environments

   *  Starve critical energy-aware flows by congesting green paths

   Such threats can be mitigated by:

   *  Incorporating energy fairness into policy logic

   *  Monitoring for unusual shifts in energy path usage

   *  Reserving minimum energy budgets for critical DSCP classes

7.5.  Inter-domain Trust and Policy Consistency

   In multi-domain deployments (e.g., federated edge-cloud or SD-WAN),
   DSCP interpretations and energy policies may vary across domains.
   Without consistent trust models, forwarding domains may ignore,
   alter, or misinterpret DSCP markings.  To prevent this:

   *  Domains SHOULD negotiate DSCP-to-policy mappings where possible





C. Sofia & Ali           Expires 7 January 2026                [Page 15]

Internet-Draft            Energy-aware DiffServ                July 2025


   *  Border routers MUST apply local enforcement and telemetry
      filtering

   *  DSCP field usage SHOULD be aligned with IANA and IETF-recommended
      classes

8.  References

8.1.  Normative References

   [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
              Requirement Levels", BCP 14, RFC 2119,
              DOI 10.17487/RFC2119, March 1997,
              <https://www.rfc-editor.org/info/rfc2119>.

   [RFC8174]  Leiba, B., "Ambiguity of Uppercase vs Lowercase in RFC
              2119 Key Words", BCP 14, RFC 8174, DOI 10.17487/RFC8174,
              May 2017, <https://www.rfc-editor.org/info/rfc8174>.

   [RFC2474]  Nichols, K., Blake, S., Baker, F., and D. Black,
              "Definition of the Differentiated Services Field (DS
              Field) in the IPv4 and IPv6 Headers", RFC 2474,
              DOI 10.17487/RFC2474, December 1998,
              <https://www.rfc-editor.org/info/rfc2474>.

   [RFC2475]  Blake, S., Black, D., Carlson, M., Davies, E., Wang, Z.,
              and W. Weiss, "An Architecture for Differentiated
              Services", RFC 2475, DOI 10.17487/RFC2475, December 1998,
              <https://www.rfc-editor.org/info/rfc2475>.

   [RFC4594]  Babiarz, J., Chan, K., and F. Baker, "Configuration
              Guidelines for DiffServ Service Classes", RFC 4594,
              DOI 10.17487/RFC4594, August 2006,
              <https://www.rfc-editor.org/info/rfc4594>.

   [RFC9197]  Brockners, F., Ed., Bhandari, S., Ed., and T. Mizrahi,
              Ed., "Data Fields for In Situ Operations, Administration,
              and Maintenance (IOAM)", RFC 9197, DOI 10.17487/RFC9197,
              May 2022, <https://www.rfc-editor.org/info/rfc9197>.

8.2.  Informative References

   [codeco]   C. Sofia et al., R., ""A Framework for Cognitive,
              Decentralized Container Orchestration," inProc. IEEE
              Access, vol. 12, pp. 79978-80008, 2024, doi: 10.1109/
              ACCESS.2024.3406861.", 2024.





C. Sofia & Ali           Expires 7 January 2026                [Page 16]

Internet-Draft            Energy-aware DiffServ                July 2025


   [codeco_d10]
              C. Sofia et al., R., ""CODECO Deliverable D10 -
              Technological Guidelines, Reference Architecture, and
              Open-source Ecosystem
              Design.https://doi.org/10.5281/zenodo.12819444", 2024.

Acknowledgements

   This work has been funded by The European Commission in the context
   of the Horizon Europe CODECO project under grant number 101092696,
   and by SGC, Grant agreement nr: M-0626, project SemComIIoT.  We thank
   the following colleagues for their discussions concerning network
   probing and exposure as well as application workload scheduling
   aspects:

   *  Alberto del Rio, Universidad Politecnica de Madrid, for
      contributions for active probing.

   *  Kaikang Huang, fortiss, for contributions on energy-efficient
      network telemetry and probing

   *  Tina Samizadeh, fortiss, for contributions on scheduling
      benchmarking

   *  Alejandro Muniz, Telefonica, for contributions on network exposure

   *  Luis Miguel Contreras Murillo, Telefonica, for contributions on
      network exposure

Authors' Addresses

   Rute C. Sofia
   fortiss GmbH
   Guerickestr. 25
   80805 Munich
   Germany
   Email: sofia@fortiss.org
   URI:   www.rutesofia.com


   Dalal Ali
   fortiss GmbH
   Guerickestr. 25
   80805 Munich
   Germany
   Email: ali@fortiss.org





C. Sofia & Ali           Expires 7 January 2026                [Page 17]